| Nguzo | Ukadiriaji wa Yaani | Uc | Matumizi ya nguvu | Nguvu ya Juu | ||
| AC-7a | AC-7b | (VAC)(50Hz) | Subiri | Vuta ndani | ||
| 2P | 16A | 6A | 230 | 2.1VA | 2.1VA | 2.0W |
| 20A | 7A | 230 | 2.1VA | 2.1VA | 2.0W | |
| 25A | 9A | 230 | 2.1VA | 2.1VA | 2.0W | |
| 32A | 12A | 230 | 2.1VA | 2.1VA | 2.0W | |
| 40A | 18A | 230 | 2.3VA | 2.3VA | 2.0W | |
| 63A | 25A | 230 | 2.3VA | 2.3VA | 2.0W | |
| 4P | 16A | 6A | 230 | 2.3VA | 2.3VA | 2.0W |
| 20A | 7A | 230 | 2.3VA | 2.3VA | 2.0W | |
| 25A | 9A | 230 | 2.3VA | 2.3VA | 2.0W | |
| 32A | 12A | 230 | 2.3VA | 2.3VA | 2.0W | |
| 40A | 18A | 230 | 6.0VA | 6.0VA | 5.5W | |
| 63A | 25A | 230 | 6.0VA | 6.0VA | 5.5W | |
Mawasiliano Saidizi
Mawasiliano Saidizi ni kiashiria cha hali ya mawasiliano ya mwasiliani. Zima au Zima.
| AC-12 | AC-15 | DC-13 | Imekadiriwa Sasa | ||||
| CV | CA | CV | CA | CV | CA | ||
| BMC7-AUC11 | 240V | 5A | 230V | 2A | DC 130V | 1A | 5A |
| BMC7-AUC20 | 240V | 5A | 230V | 2A | DC 130V | 1A | 5A |
Kipande cha nafasi
Vipu vya nafasi hutumika kupunguza ongezeko la joto la vifaa vilivyowekwa kando, inashauriwa kutenganisha vifaa vya kielektroniki
(vifaa vya kurekebisha halijoto, kipima muda kinachoweza kupangwa n.k.,) kutoka kwa vifaa vya kielektroniki vya mitambo (rela za msukumo, vidhibiti)
| Vipimo vya kiufundi | |
| Kipande cha nafasi | Kipande cha nafasi cha 3mm |
| Kipande cha nafasi cha 9mm |
Kigezo kikuu na utendaji wa kiufundi
| Saketi ya umeme | ||
| Ukadiriaji wa volteji (Ue) | 1P, 2P | AC ya 250V |
| 3P, 4P | AC ya 400V | |
| Masafa | 50/60Hz | |
| Uvumilivu (OC) | Mizunguko 1,000,000 | |
| Umeme | Mizunguko 100,000 | |
| Idadi ya juu zaidi ya uendeshaji wa kubadili kwa siku | 100 | |
| Volti ya insulation (Ui) | AC ya 500V | |
| Kiwango cha uchafuzi wa mazingira | 2 | |
| Volti ya kuhimili msukumo iliyokadiriwa (Uimp) | 2.5kV(4kV kwa 12/24/48VAC) | |
| Kiwango cha ulinzi (IEC 60529) | Kifaa pekee | IP20 |
| Kifaa katika sehemu ya moduli | IP40 | |
| Halijoto ya uendeshaji | -5ºC~+60ºC | |
| Halijoto ya kuhifadhi | -40ºC~+70ºC | |
| Uenezaji wa Tropiki (IEC 60068.1) | Matibabu ya 2 (unyevu kiasi 95% kwa nyuzi joto 55°C | |
| Utiifu wa ELSV (Volti ya Usalama wa Ziada ya Chini) kwa matoleo ya 12/24/48vac | ||
| Udhibiti wa bidhaa unafuata mahitaji ya SELV (usalama wa ziada wa volteji ya chini) | ||
Kumbuka: Katika kesi ya kuweka kiunganishi kwenye sehemu iliyofungwa ambayo halijoto ya ndani iko kati ya 50ºC na 60ºC, ni muhimu kutumia nafasi, kati ya kila kiunganishi.