Mfululizo wa CRS-100,120 ni usambazaji wa umeme wa 100,120W wa kundi moja uliofungwa na muundo wa wasifu wa chini wa 30mm, kwa kutumia pembejeo kamili ya AC ya 85-264VAC, mfululizo mzima hutoa 5V,12V,15V,24V,36V na 48V pato.
Aina | Viashiria vya kiufundi | |||||
Pato | DC voltage | 5V | 12V | 24V | 36V | 48V |
Iliyokadiriwa sasa | 18A | 8.5A | 4.5A | 2.8A | 2.3A | |
Nguvu iliyokadiriwa | 90W | 102W | 108W | 100.8W | 110.4W | |
Ripple na kelele | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Kiwango cha udhibiti wa voltage | ±10% | |||||
Usahihi wa voltage | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Kiwango cha marekebisho ya mstari | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Kiwango cha udhibiti wa mzigo | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Angaza wakati | 500ms, 300ms/230VAC 500ms, 30ms/115VAC (mzigo kamili) | |||||
Weka wakati | 55ms/230VAC 10ms/115VA(mzigo kamili) | |||||
Ingizo | Kiwango cha voltage / frequency | 85-264VAC/120-373VDC 47Hz-63Hz | ||||
Ufanisi (kawaida) | 86% | 88% | 90% | 90.50% | 91% | |
Kazi ya sasa | 1.9A/115VAC 1.2A/230VAC | |||||
Mshtuko wa sasa | Mwanzo wa baridi: 50A/230VAC | |||||
Uvujaji wa sasa | <1mA 240VAC | |||||
Tabia za ulinzi | Ulinzi wa upakiaji | Aina ya ulinzi: hali ya burp, ondoa hali isiyo ya kawaida na urejee kwa kawaida kiotomatiki | ||||
Ulinzi wa overvoltage | Aina ya ulinzi: funga pato na uwashe upya kiotomatiki hadi kawaida | |||||
Sayansi ya Mazingira | Joto la kufanya kazi na unyevu | -30℃~+70℃;20%~90RH | ||||
Joto la kuhifadhi na unyevu | -40℃~+85℃;10%~95RH | |||||
Usalama | Upinzani wa shinikizo | Ingizo – pato :4KVAC-kesi ingizo :2KVAC pato -kesi: 1.25kvac muda :1 dakika | ||||
Impedans ya insulation | Ingizo – pato na ingizo – ganda, pato – ganda: 500 VDC /100 m Ω 25℃,70% RH | |||||
Nyingine | Ukubwa | 129*97*30mm(L*W*H) | ||||
Uzito wa jumla / uzito wa jumla | 340g/365g | |||||
Maoni | (1)Kipimo cha ripple na kelele: Kwa kutumia 12″jozi-iliyopinda laini yenye capacitor ya 0.1uF na 47uF sambamba kwenye terminal, kipimo kinafanywa kwa kipimo data cha 20MHz. (2) Ufanisi hujaribiwa kwa voltage ya pembejeo ya 230VAC, mzigo uliokadiriwa na 25 ℃ joto iliyoko. Usahihi: ikiwa ni pamoja na hitilafu ya kuweka, kiwango cha urekebishaji wa mstari na kiwango cha kurekebisha mzigo. Mbinu ya mtihani wa kiwango cha marekebisho ya mstari: kuinua kutoka kwa voltage ya chini hadi voltage ya juu njia ya mtihani wa kiwango cha urekebishaji uliokadiriwa: kutoka 0% -100% iliyokadiriwa mzigo. Muda wa kuanza hupimwa katika hali ya baridi ya kuanza, na mashine ya kubadili mara kwa mara ya haraka inaweza kuongeza muda wa kuanza. Wakati urefu ni zaidi ya mita 2o000, joto la uendeshaji linapaswa kupunguzwa na 5/1000. |