| Aina | Viashiria vya kiufundi | |||||
| Matokeo | Volti ya DC | 5V | 12V | 24V | 36V | 48V |
| Imekadiriwa mkondo | 7A | 3A | 1.5A | 1A | 0.8A | |
| Nguvu iliyokadiriwa | 35W | 36W | 36W | 36W | 38.4W | |
| Mlipuko na kelele | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
| Kiwango cha udhibiti wa volteji | ± 10% | |||||
| Usahihi wa volteji | ± 2.0% | ± 1.0% | ± 1.0% | ± 1.0% | ± 1.0% | |
| Kiwango cha marekebisho ya mstari | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |
| Kiwango cha udhibiti wa mzigo | ± 1.0% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |
| Muda wa kuamka | 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC (mzigo kamili) | |||||
| Weka muda | 30ms/230VAC 12ms/115VA (mzigo kamili) | |||||
| Ingizo | Masafa/voltage | 85-264VAC/120-373VDC 47Hz-63Hz | ||||
| Ufanisi (wa kawaida) | 82% | 86% | 88% | 88% | 89% | |
| Mkondo wa kufanya kazi | 0.7A/115VAC 0.42A/230VAC | |||||
| Mkondo wa mshtuko | Kuanza kwa baridi: 45A/230VAC | |||||
| Mkondo wa kuvuja | <0.75mA 240VAC | |||||
| Sifa za ulinzi | Ulinzi wa mzigo kupita kiasi | Aina ya ulinzi: hali ya kupasuka, ondoa hali isiyo ya kawaida na urudi kiotomatiki katika hali ya kawaida | ||||
| Ulinzi wa volteji nyingi | Aina ya ulinzi: funga pato na uanze upya kiotomatiki hadi hali ya kawaida | |||||
| Sayansi ya mazingira | Halijoto na unyevunyevu wa kufanya kazi | -30ºC~+70ºC;20%~90RH | ||||
| Halijoto na unyevunyevu wa hifadhi | -40ºC~+85ºC;10%~95RH | |||||
| Usalama | Upinzani wa shinikizo | Ingizo - matokeo :4KVAC ingizo-sanduku :2KVAC matokeo -sanduku: 1.25kvac muda :dakika 1 | ||||
| impedansi ya insulation | Ingizo - matokeo na ingizo - ganda, matokeo - ganda: 500 VDC /100mΩ 25ºC, 70% RH | |||||
| Nyingine | Ukubwa | 98*82*30mm | ||||
| Uzito halisi / uzito jumla | 230g/246g | |||||
| Maoni | (1) Kipimo cha mawimbi na kelele: Kwa kutumia laini ya jozi 12 iliyosokotwa yenye kipaza sauti cha 0.1uF na 47uF sambamba kwenye kituo, kipimo kinafanywa kwa kipimo data cha 20MHz. | |||||
| (2) Ufanisi hujaribiwa kwa volteji ya kuingiza ya 230VAC, mzigo uliokadiriwa na halijoto ya mazingira ya 25ºC. Usahihi: ikiwa ni pamoja na hitilafu ya mpangilio, kiwango cha marekebisho ya mstari na kiwango cha marekebisho ya mzigo. Njia ya majaribio ya kiwango cha marekebisho ya mstari: kupima kutoka volteji ya chini hadi volteji ya juu kwa mzigo uliokadiriwa Njia ya majaribio ya kiwango cha marekebisho ya mzigo: kutoka 0%-100% mzigo uliokadiriwa. Muda wa kuanza hupimwa katika hali ya kuanza kwa baridi, na mashine ya kubadili mara kwa mara ya haraka inaweza kuongeza muda wa kuanza. Wakati urefu uko juu ya mita 2000, halijoto ya uendeshaji inapaswa kupunguzwa kwa 5/1000. | ||||||