Aina | Viashiria vya kiufundi | |||||
Pato | DC voltage | 5V | 12V | 24V | 36V | 48V |
Iliyokadiriwa sasa | 7A | 3A | 1.5A | 1A | 0.8A | |
Nguvu iliyokadiriwa | 35W | 36W | 36W | 36W | 38.4W | |
Ripple na kelele | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Kiwango cha udhibiti wa voltage | ±10% | |||||
Usahihi wa voltage | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Kiwango cha marekebisho ya mstari | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Kiwango cha udhibiti wa mzigo | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Angaza wakati | 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC (mzigo kamili) | |||||
Weka wakati | 30ms/230VAC 12ms/115VA(mzigo kamili) | |||||
Ingizo | Kiwango cha voltage / frequency | 85-264VAC/120-373VDC 47Hz-63Hz | ||||
Ufanisi (kawaida) | 82% | 86% | 88% | 88% | 89% | |
Kazi ya sasa | 0.7A/115VAC 0.42A/230VAC | |||||
Mshtuko wa sasa | Mwanzo wa baridi: 45A/230VAC | |||||
Uvujaji wa sasa | <0.75mA 240VAC | |||||
Tabia za ulinzi | Ulinzi wa upakiaji | Aina ya ulinzi: hali ya burp, ondoa hali isiyo ya kawaida na urejee kwa kawaida kiotomatiki | ||||
Ulinzi wa overvoltage | Aina ya ulinzi: funga pato na uwashe upya kiotomatiki hadi kawaida | |||||
Sayansi ya Mazingira | Joto la kufanya kazi na unyevu | -30℃~+70℃;20%~90RH | ||||
Joto la kuhifadhi na unyevu | -40℃~+85℃;10%~95RH | |||||
Usalama | Upinzani wa shinikizo | Ingizo – pato :4KVAC-kesi ingizo :2KVAC pato -kesi: 1.25kvac muda :1 dakika | ||||
Impedans ya insulation | Ingizo – pato na ingizo – ganda, pato – ganda: 500 VDC /100mΩ 25℃,70% RH | |||||
Nyingine | Ukubwa | 98*82*30mm | ||||
Uzito wa jumla / uzito wa jumla | 230g/246g | |||||
Maoni | (1)Kipimo cha ripple na kelele: Kwa kutumia 12 "laini ya jozi-iliyosokotwa yenye capacitor ya 0.1uF na 47uF sambamba kwenye terminal, kipimo kinafanywa kwa kipimo data cha 20MHz. (2) Ufanisi hujaribiwa kwa voltage ya pembejeo ya 230VAC, mzigo uliokadiriwa na 25 ℃ halijoto iliyoko. Usahihi: ikijumuisha hitilafu ya mpangilio, kiwango cha urekebishaji wa mstari na kiwango cha kurekebisha mzigo. Mbinu ya mtihani wa kiwango cha marekebisho ya mstari: kupima kutoka kwa voltage ya chini hadi voltage ya juu Njia ya mtihani wa kiwango cha urekebishaji uliokadiriwa: kutoka 0% -100% iliyokadiriwa mzigo. Muda wa kuanza hupimwa katika hali ya baridi ya kuanza, na mashine ya kubadili mara kwa mara ya haraka inaweza kuongeza muda wa kuanza. Wakati mwinuko uko juu ya mita 2000, joto la uendeshaji linapaswa kupunguzwa na 5/1000. |